Original instructions, Electrical installation, Connections – Rockwell Automation 445L GuardShield Safe 2 and Safe 2 PAC Safety Light Curtains User Manual User Manual
Page 13: Safe 2 shock mounting kit, Power supply, Figure 11: different mounting brackets for safe 2
R
GuardShield™ Safe 2 Safety Light Curtain User Manual
11
Original instructions
Figure 11: Different mounting brackets for Safe 2
Safe 2 Shock Mounting Kit
Rockwell Automation offers a shock and vibration isolation kit for
vertically mounting the Safe 2. This kit is most effective in protecting the
internal optical and electronic components of the Safe 2 light curtain.
The best performance of the shock and vibration isolation kit is attained
when the kit is used in conjunction with the Safe 2 vertical mounting
brackets (445L-AF6144).
Figure 12: Shock Isolator
Electrical Installation
Connections
Power Supply
The external voltage supply (+24V DC) must meet the requirements of
IEC 61496-1. In addition, the following requirements have to be
fulfilled:
• A short-term power failure of 20 ms must be bridged by the power
supply.
• The power supply has double insulation between the primary and
the secondary side.
• The power supply is protected against overload.
• The power supply corresponds to the guidelines of the EWG
(industrial environment).
• The power supply corresponds to the Low Voltage Directives.
• The grounded conductor of the power supply device must be
connected to a grounded conductor PE.
• The maximum deviation of the voltage levels is 24V DC +/- 20%.
445L-AF6140
Standard mounting brackets—supplied with each
light curtain
For side mounting
Adjustable by
± 4°
(Two brackets per kit.)
445L-AF6144
Vertical mounting brackets (optional)
For mounting in the vertical axis of the light curtain
Adjustable by
± 4°
(Two brackets per kit.)
445L-AF6141
180° Mounting, rotation ±90°, for applications
where the mounting angle is not set using the
mounting frame.
(Two brackets per kit.)
29.5
(1.16)
M6x40
M4x16
11
(0.43)
M6x60
M4x12
11
17
(0.67)
135
(5.31)
40.8
(1.60)
70
(2.76)
36.4
(1.43)
37
(1.46)
M6
20
(0.79) dia.
M 6x25 Socket head cap screw, fully threaded
M 6x6.1/14 Lock washer
M 6x6.1/14 Lock washer
Vibration damper
18
(0.71)
20
(0.79)
Double insulation
This part of the insulation provides
supplementary insulation against
hazardous voltage levels.
Motor, etc.
Hazardous voltage level
Basic insulation
Hazardous
voltage level
Hazardous
voltage level
Reinforced
insulation or
double
insulation
Unit 1
Power
Supply
Unit 2
Output (pink
and grey)
Basic insulation
Basic insulation
0V (blue)
+24V (brown)
K1
K1
K2
K2
Guard
Shield