beautypg.com

Rockwell Automation 284G ArmorStart - Getting Started User Manual

Page 15

background image

Publication 284G-QS001A-EN-P - December 2008

15

Table 6

Basic Program Group for Sensorless Vector Control

➊ Stop drive before changing this parameter.
➋ See Important below:

Parameter

Number

Parameter

Description

Display/

Options

Min./

Max.

Defaults
Settings

131

Motor NP Volts

1 VAC

20/Drive Rated

Volts

Based on

Driving

Rating

132

Motor NP Hz

1 Hz

15/400 Hz

60 Hz

133

Motor OL

Current

0.1 A

0.0/(Drive Rated

Amps x 2)

Based on

Driving

Rating

134

Minimum Freq.

0.1 Hz

0.0/400 Hz

0.0 Hz

135

Maximum

Freq.

0.1 Hz

0.0/400 Hz

60 Hz

136

Start Source

0 = Keypad ➋

1 = 3-Wire ➋

2 = 2-Wire

3 = 2-W Lvl Sens

4 = 2-W Hi Speed

5 = Comm Port

0/5

5

137

Stop Mode

0 = Ramp, CF

1 = Coast, CF

2 = DC Brake, CF

3 = DCBrkAuto, CF

4 = Ramp

5 = Coast

6 = DC Brake

7 = DC BrakeAuto

8 = Ramp + EM B, CF

9 = Ramp + EM Brk

0/9

9

138

Speed

Reference

0 = Drive Pot ➋

1 = InternalFreq

2 = 0…10V Input ➋

3 = 4…20 mA Input ➋

4 = Preset Freq

5 = Comm Port

6 = Stp Logic

7 = Anlg in Mult ➋

0/7

5

139

Accel Time 1

0.1 Secs

0.0/600.0 Secs

10.0 Secs

140

Decel Time 1

0.1 Secs

0.0/600.0 Secs

10.0 Secs

141

Reset to

Default

0 = Ready/Idle

1 = FactoryRset

0/1

0

IMPORTANT

These drive parameters options will cause the
Bulletin 284G ArmorStart Distributed Motor Controller
to become disabled.