Step 3 - basic programming, Menu structure hierarchy stopped – Rockwell Automation 150 SMC Flex Quick Start User Manual
Page 11
SMC™ Flex Quick Start 11
Step 3 - Basic Programming
The SMC-Flex controller can be programmed with the built-in keypad and LCD display or with an optional
Bulletin 20-HIM-xx LCD human interface module.
Parameters
Diagnostics
Preferences
Memory
Storage
Log In *
See File Structure Below for
additional details
Alarms
Faults
Device Revision
Change Password
User Dspl Line
User Dspl Time
User Dspl Video
Reset User Display
Reset to Defaults
Enter Password
(* - Only Active when a password is used)
Main Menu
Monitoring
Volts Phase A-B
Volts Phase B-C
Volts Phase C-A
Current Phase A
Current Phase B
Current Phase C
Watt Meter
Kilowatt Hours
Elapsed Time
Meter Reset
Power Factor
Mtr Thermal Usage
Set Up
Motor Protection
Communications
Utility
Linear List
Basic
SMC Option
Motor Connection
Line Voltage
Starting Mode
Ramp Time
Initial Torque
Cur Limit Lvl
Kickstart Time
Kickstart Level
Stop Input
Option 1 Input
Option 2 Input
Stop Mode
Stop Time
Overload Class
Service Factor
Motor FLC
Overload Reset
Aux1 Config
Aux2 Config
Aux3 Config
Aux4 Config
Parameter Mgt
Metering
Overload
Underload
Undervoltage
Overvoltage
Unbalance
Jam
Stall
Ground Fault
PTC
Phase Reversal
Restart
Overload Class
Service Factor
Motor FLC
Overload Reset
Overload A Lvl
Parameter Mgmt
Underload F Lvl
Underload F Dly
Underload A Lvl
Underload A Dly
Parameter Mgmt
Undervoltage F Lvl
Undervoltage F Dly
Undervoltage A Lvl
Undervoltage A Dly
Parameter Mgmt
Overvoltage F Lvl
Overvoltage F Dly
Overvoltage A Lvl
Overvoltage A Dly
Parameter Mgmt
Unbalance F Lvl
Unbalance F Dly
Unbalance A Lvl
Unbalance A Dly
Parameter Mgmt
Jam F Lvl
Jam F Dly
Jam A Lvl
Jam A Dly
Parameter Mgmt
Stall Delay
Parameter Mgmt
Gnd Flt Enable
Gnd Flt Lvl
Gnd Flt Dly
Gnd Flt Inh Time
Gnd Flt A Enable
Gnd Flt A Lvl
Gnd Flt A Dly
Parameter Mgmt
PTC Enable
Parameter Mgmt
Phase Reversal
Parameter Mgmt
Starts Per Hour
Restart Attempts
Restart Delay
Parameter Mgmt
Comm Masks
Data Links
Logic Mask
Parameter Mgmt
Data In A1
Data In A2
Data In B1
Data In B2
Data In C1
Data In C2
Data In D1
Data In D2
Data Out A1
Data Out A2
Data Out B1
Data Out B2
Data Out C1
Data Out C2
Data Out D1
Data Out D2
Parameter Mgmt
Language
Motor Data
Language
Parameter Mgmt
Motor FLC
Motor ID
Parameter Mgmt
Linear List
All Parameters
Menu Structure Hierarchy
Stopped
---
0.0
0.0
0.0
Amps
Volt
%MTU
Power Up and Status Display
Note:
•
Depending on the SMC option, additional
parameters may appear in some menus
•
The external HIM has similar programming
operation to the built-in HIM, however some
differences do exist.
•
The built-in HIM can not be used to program
other DPI devices (i.e. Device Select)