Rockwell Automation 21G 750-Series POD Remote Mounting Kit User Manual
Installation instructions, Kit contents, Additional materials
Installation Instructions
PowerFlex 750-Series Control Pod Remote Mounting Kit
PowerFlex 750-Series Control Pod Remote Mounting Kit is used to install the
control pod in a cabinet that is separate from a Frame 8 or larger drive.
For additional general information, refer to:
Kit Contents
The Control Pod Remote Mounting Kit (20-750-RPD1-F8) contains the
following materials.
Additional Materials
When the factory installed control pod is being removed from the drive for
remote mounting, the user must also obtain the Converter Right Cover (no
POD) kit (SK-R1-CCVR2-F8). This kit contains the following materials.
Title
Publication
Available Online at …
PowerFlex 750-Series AC Drives Installation
Instructions
750-IN001
PowerFlex 750-Series AC Drives (Frame 8) Hardware
Service Manual
750-TG001
Wiring and Grounding Guidelines for PWM AC Drives DRIVES-IN001
Guarding Against Electrostatic Damage
8000-4.5.2
Item
Quantity
Description
24V Power Wiring Harness
1
23 m (75 ft) wire harness for internal 24V
supply on converter at P14 on the fiber
interface board.
Inverter Fiber-optic Cable
2
23 m (75 ft) fiber-optic cable connects fiber
interface board and the power layer board.
Fiber-optic Transceiver
2
Transceiver for fiber-optic cable connections
to the converter gate board and the fiber
interface board. (Needed when the drive is
shipped with no POD from the factory.)
External Power Supply Connector
1
Three position connector for optional user-
supplied 24V power connection at P13 on the
fiber interface board.
Twist-Lock Cable Support
3
Supports 24V power wiring harness in the
pod.
M4 x 12 mm Long Self-Tapping Screw
4
Used to mount the control pod to a panel.
M4 x 12 mm Long Machine Screw
3
Used to mount cable supports.
Item
Quantity
Description
Cover
1
Converter Right Cover for no POD.
Bracket
2
Brackets used to support left side of cover.
M5 x 14 mm Long Machine Screw
6
Used to secure the brackets and cover to the
converter panel.