General specifications (continued), Description – Rockwell Automation 45PVA Part Verification Array User Manual
Page 2
2
General Specifications (continued)
Description
45PVA–1LEB1–F4
45PVA–1LEB2–F4
45PVA–1LEB3–F4
45PVA–1LEB4–F4
45PVA–2LEA1–F4
45PVA–2LEA2–F4
Cross Talk Elimination
Selectable Frequency
Material
Enclosure: Aluminum, Lens: Polycarbonate, End plate: Resin
Wiring
4-Pin DC Micro Connection with 2m pigtail
Environmental Characteristics
Ambient Light
10,000 lx (Max.)
Operating TemperatureĊC (F)
0
…50_ (32…122_)
-10
…50_ (14…122_)
Storage TemperatureĊC (F)
–25
…70_ (–13…158_)
Operating Humidity
35% to 85 %RH
Enclosure Protection
IP 62
Vibration Resistance
10Hz to 55Hz, 1.5mm Amplitude, 2 hours, X,Y and Z directions
Shock Resistance
500 m/s
2
3 times X,Y and Z directions
Dielectric Strength
1,000VAC for 1 minute
Description
Transmitter
Receiver
Switch Cover
Cable (Gray)
Power Indicator
(Green)
Dark Indicator
(Orange)
Switch Cover
Job Indicator (Green)
Warning Indicator (Red)
(optional functionality)
Job Indicator
(Green)
Light Status Indicator
(Green/Orange)
Cable (Black)
Mode Selection Switches
Retroreflective/Diffuse
Output Indicator
(Orange)
Switch Cover
Job Indicator (Green)
Warning Indicator (Red)
(optional functionality)
Power Indicator (Green)
(Blinks orange during
power up sensitivity
adjustment)
Cable (Black)
Auto Adjust
Freq A
PNP
Auto Adj Off
Freq B
NPN
Retro
1
2
3
4
5
6
Fast
A
PNP
Slow
B
NPN
Light
1
2
3
4
5
6
Warning_on
Dark_on
Flash
Warning_off
Light_on
Retroreflective/Diffuse
1. Operating mode selection
2. Automatic sensitivity adjustment ON/OFF
3. Output Normally Open/Normally Closed
4. Selectable warning indicator
5. NPN/PNP selectable switch
6. Selectable frequency
Mode Selection Switches
Transmitted Beam
1. Job indicator mode
2. Job indicator speed control for flashing
3. Selectable operation mode (receiver only)
4. Selectable warning indicator (receiver only)
5. NPN/PNP selectable switch
6. Selectable frequency
Factory Default Settings
Diffuse
N.O.
Warning_on
N.C.
Warning_off
Note: Only operate the mode selection switches with the power supply turned off.