PowerFlex® DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

6. Remove the appropriate gate leads (refer to

Figure 1 on page 10

for

location):

For regenerative drives, remove each pair of (orange and yellow) gate

lead cables from connectors KG01…KG06 and KG1…KG6 and push
each lead through the appropriate opening in the board.

For non-regenerative drives, remove each pair of (orange and yellow)

gate lead cables from connectors KG01…KG06 and push each lead
through the appropriate opening in the board.

Important: Remove the gate leads by grasping the connector and

pulling up. DO NOT pull the gate leads off by pulling on
the wires.

7. Remove the cable from connectors XTA on the Pulse Transformer

board (refer to

Figure 1 on page 10

for location).

Remove cable
from XTA

For regenerative
drives, remove 12
gate leads and
push through holes
in board

Remove cable
from XTA

For non-regenerative
drives, remove six
gate leads and push
through holes in
board