Custom firmware parameters – Rockwell Automation 20B PowerFlex 700 Custom Firmware - Pump Off User Manual
Page 5
PowerFlex 700 with Vector Control Option Custom Firmware 5
Rockwell Automation Publication 20B-IN020C-EN-P - January 2014
Custom Firmware Parameters
Advanced Parameter View must be selected (parameter 196 [Param Access Lvl] set to 1,
“Advanced”).
Parameters 692 through 699 provide various metering points for the function. Refer to pages
8
and
9
for descriptions.
Custom Firmware Parameters
Fi
le
Gr
oup
No
.
Parameter Name and Description
See User Manual for symbol descriptions
Values
Re
lated
APPLIC
AT
IONS
O
il W
ell Pump
680 [Pump Cycle Store]
Used to store the torque waveform over the course of a
pump cycle. This is used to determine the downstoke when
in “Automatic” or “Position” mode.
With the drive running at the desired speed, change [Pump
Cycle Store] to “Enabled” and press enter. Over the next few
cycles the waveform is stored and [Pump Cycle Store]
changes back to “Disabled”.
If after 5 pump cycles [Pump Cycle Store] has not changed
back to “Disabled”, waveform variations can be excessive.
Default:
Options:
0
0
1
“Disabled”
“Disabled”
“Enabled”
681 [Set Top of Strok]
Stores the top of pump stroke cycle.
With the drive running at the desired speed, change [Set Top
of Strok] to “Enabled” and press enter when the rod is at the
highest position. [Set Top of Strok] automatically changes
back to “Disabled”.
Default:
Options:
0
0
1
“Disabled”
“Disabled”
“Enabled”
682 [Pump Off Control]
Used to enable Pump Off control.
Default:
Options:
0
0
1
2
“Disabled”
“Disabled”
“Baseline Set”
“Fixed Setpt”
“Disabled” (0) - Pump Off control is not active.
“Baseline Set” (1) - The control uses a torque baseline created after any start of the drive (first ten cycles).
IMPORTANT: It is critical that this data is gathered from a full well.
“Fixed Setpt” (2) - The control uses the value in [Torque Setpoint]. Use the value in [% Drop Torque] as a
guideline in “Automatic” or “Position” mode. In “Cycle” mode use [% Cycle Torque] as a guideline.