Installation of flashing – USG Durock Tile Membrane User Manual
Page 6
Use the trowel’s smooth edge
to fully embed the material.
4. For inside corners, provide a
relief cut, but place adhesive
where the membrane folds
over itself to ensure a water-
durable connection. Overlap
butt joints by 1-1/29 and
use the mastic to ensure a
water-durable connection.
Apply adhesive to the vertical
and horizontal legs of the butt
joint. Work the material care-
fully into position and smooth
out, using the flat edge of
the trowel.
5. Allow membrane to cure
adequately before setting tile.
6
If flashing is required:
1. Cut 39- 49 strip from end of
D
urock
tile membrane roll.
Pre-crease the material in
half lengthwise, with half to
be adhered to the floor and
half to the vertical surface.
Install all corner pieces first,
then fill in between corners
around the perimeter as
necessary.
2. Apply Durock tile membrane
adhesive with a 3/89-nap paint
roller or a 1/169 U-notch
trowel; apply Type 1 organic
adhesive or latex-modified
thin-set mortar with a 1/169
U-notch trowel.
3. Install membrane with the
cementitious side out. For
outside corners, make a relief
cut and press into adhesive.
Installation of
Flashing