Application

Monolithic Concrete

Prepare the surface with USG Plaster Bonder applied according to the directions. Fill all

(continued)

voids and depressions with D

IAMOND

Brand Veneer Basecoat Plaster and allow to set and partially dry. Then apply

D

IAMOND

Brand Veneer Basecoat Plaster as with gypsum base or concrete block (above).

Important:

As no suction

is provided over surfaces treated with the plaster bonding agent, it is essential that the applied basecoat surface
be raked or broomed once the material has become firm for a rough and open surface to provide proper suction
for the finish coat. Failure to do so may result in delamination of the finish material.

F

IBEROCK

Brand Abuse-Resistant Panels

Veneer Plasters provide increased resistance to abrasion, indentation and

penetration when used over F

IBEROCK

Brand Abuse-Resistant Panels in commercial and institutional applications

such as schools and high-traffic retail locations. Depending on expectations for abrasion, indentation and impact
resistance, the finish plaster may also be I

MPERIAL

Brand Finish Plaster, D

IAMOND

Brand Interior Finish, R

ED

T

OP

Finish or any lime-gauging finish combination.

In this two-coat veneer plaster system, D

IAMOND

Brand Veneer Basecoat Plaster and one of the finishes indicated

above are applied over F

IBEROCK

Brand Abuse-Resistant Panels attached to framing. Space wood or steel framing

16

Љ o.c. or 24Љ o.c. Position all ends and edges of panels over framing members, except when joints are at right

angles to framing members, as in perpendicular application or when end joints are back-blocked. On walls, fas-
teners are spaced a maximum of 12

Љ o.c. when framing spacing is 24Љ o.c., or 16Љ o.c. when framing spacing is

16

Љ o.c. For ceiling applications, nails should be spaced no more than 7Љ o.c., screws, 12Љ o.c. Prior to treatment

of panel joints, apply USG Plaster Bonder in a continuous film to joint area according to application directions.

Joints of the panels are treated using S

HEETROCK

Brand Joint Tape and a S

HEETROCK

Brand Setting-Type Joint

Compound (D

URABOND

or E

ASY

S

AND

). Provide an additional coat of setting-type compound to fully conceal the

tape. Allow to completely dry. When the joints are completely dry, treat the entire wall surface with USG Plaster
Bonder according to the application directions. Then apply D

IAMOND

Brand Veneer Basecoat Plaster 1/16

Љ to

3/32

Љ thick using scratch and double-back technique. This is accomplished by applying a tight, thin coat over

the entire area, and immediately doubling back with plaster from the same batch to achieve full thickness. When
basecoat plaster is firm, broom the surface to leave it rough and open for finish. With basecoat set and partially
dry, apply I

MPERIAL

Brand Finish Plaster using a scratch and double-back technique. Complete finishing when

material is firm. Leave finished surface smooth and dense for decorating.

Note that 5/8

Љ F

IBEROCK

Brand Abuse-Resistant Panels can be substituted for 5/8

Љ I

MPERIAL

Brand Gypsum Base,

F

IRECODE

Core, or 1/2

Љ I

MPERIAL

Brand Gypsum Base, F

IRECODE

C Core, in any fire-rated design as long as 20-

gauge steel framing is used and the above joint treatment procedure is followed.

D

UROCK

Brand Cement Board

Veneer Plasters provide superior abrasion resistance and very good indentation and

impact resistance when used over D

UROCK

Brand Cement Board in commercial and institutional applications

such as schools and high-traffic retail locations. Depending on expectations for abrasion, indentation and impact
resistance, the finish plaster may be I

MPERIAL

Brand Finish Plaster, D

IAMOND

Brand Interior Finish, R

ED

T

OP

Finish

or any lime-gauging finish combination.

In this two-coat veneer plaster system, D

IAMOND

Brand Veneer Basecoat Plaster and one of the finishes indicated

above are applied over D

UROCK

Brand Cement Board attached to framing. Space wood or steel framing 16

Љ o.c.

Install D

UROCK

Brand Cement Panels with long edges either parallel or perpendicular to the framing and with the

rough side of the panels exposed. Fasteners are spaced a maximum of 8

Љ o.c. Prior to treatment of panel joints,

apply USG

Plaster Bonder in a continuous film to joint area according to application directions. Joints should

then be treated with S

HEETROCK

Brand Joint Tape and S

HEETROCK

Brand Setting-Type Joint Compound (D

URABOND

or E

ASY

S

AND

). Joint surfaces must be treated with a separate coat of joint compound to fully conceal the

paper tape. When the joint is completely dry, treat the entire wall surface with USG Plaster Bonder according