beautypg.com

Installation, Installation checklist, Locating your gas fireplace – Regency Horizon HZ30E Small Gas Fireplace User Manual

Page 9

background image

9

Regency Horizon™ HZ30E-1 Gas Fireplace

INSTALLATION

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label 14,000 Btu/h
(NG), 13,000 Btu/h (LP) after burning appliance
for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.

INSTALLATION

CHECKLIST

1) Locate appliance

a) Room location (Refer to "Locating Your Gas

fi replace" section)

b) Clearances to Combustibles (Refer to

"Clearances" section)

c) Mantle Clearances (Refer to "Mantel

Clearances" section)

d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section)

e) Venting Requirements (Refer to "Venting"

section)

2) Position nailing strips (Refer to "Unit Assembly

Prior to Installation).


3) Slide unit into place.

4) Remove installation access panel.

5) Install vent (Refer to "Venting Arrangement"

sections).

6) Make gas connections (Refer to "Gas Line

Installation section).

7) Make electrical connections to receptacle
supplied with unit (recommended).

8) Install 4 AA batteries into receiver/switch box

or optional AC power adaptor.

9) Test the pilot (Refer to "Pilot Adjustment"

section).

10) Test Gas Pressure (Refer to "Gas Pipe Pressure

Testing" section).

11) Install standard and optional features. Refer to

the following sections:

a)

Glass Crystals/ Optional Ceramic

Stones

b)

Optional Firebox Base Pebbles

c) Optional

Refl ective Panels

d) Optional

Fan

e) Faceplate

f)

Remote Control or Wall Thermostat


12) Reinstall installation access panel.

13) Wall Mounted ON/OFF Switch:

Use the toggle wall switch supplied with the
manual package. Use of a “decor” switch causes
higher resistance which is a problem on gas
fi replaces.

14) Final check.

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and operation fully explained to
customer
.

LOCATING YOUR

GAS FIREPLACE

1) When selecting a location for your fi replace,

ensure that the clearances are met.

2) The appliance must be installed on a fl at, solid,

continuous surface For example a wood, metal
or concrete fl oor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.

3) The HZ30E Direct Vent Gas Fireplace can be

installed in a recessed position or framed out
into the room as in A, B, C and D.

See Diagram 1.

Diagram 1

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

4) This appliance is Listed for bedroom

installations using the standard Remote
(millivolt thermostat system). Some areas may
have further requirements, check local codes
before installation.

5) The HZ30E Direct Vent Gas Fireplace

is approved for alcove installations, see
"Clearances" section for details.

6) We recommend that you plan your installation

on paper using exact measurements for
clearances and fl oor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.

Note: For vent terminations refer to "Exterior

Vent Termination Locations" section.