VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS

Vertical Venting with One(1) 90

o

Elbows (1 - 90

o =

2 - 45

o

)

The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using one
90

o

elbow, with Rigid Pipe Venting Systems.

Two 45

o

elbows equal to one 90

o

elbow, not including the

starting 45

o

elbow at the fl ue collar.

• Vent must be supported at offsets.

• Minimum distance between elbows is 1 ft. (305mm).

• Maintain clearances to combustibles as listed in the

"Clearances" section.

• Horizontal vent must be supported every 3 feet.

• Firestops are required at each fl oor level and whenever

passing through a wall.

• Must use optional rigid pipe adaptor (Part# 510-994)

when using rigid pipe vent systems.

• Refer to the "Vent Restrictor Position" section for

details on how to change the vent restrictor from the
factory setting of Set 0 to Set 1 or Set 2 if required.