beautypg.com

Installation, Framing dimensions – Regency Horizon HZ30E Small Gas Fireplace User Manual

Page 14

background image

14

Regency Horizon™ HZ30E-1 Gas Fireplace

INSTALLATION

FRAMING DIMENSIONS

A

B

C

D

G

H

Non-Combustible

Facing

Metal Stud (Header)

Metal Stud

on edge

F

E

I

J

K

L

Flex or Rigid Pipe

Finished Floor

Drywall or
other facing

C2

C1

Note: All other framing may
be of wood construction.

Framing
Dimensions

Description

HZ30E

A

Framing Height

33-5/16” (946mm)

B

Framing Width

31 - 3/16" (792mm)

C

*

Framing Depth

*

C1 Horizontal Vent 14 - 1/4" (362mm)

C2 Vertical Vent, vertical rise - terminating horizonally - 19-1/2" (495mm)

D

Minimum Height to Combustibles

Rigid 35-1/2" (902mm) | Flex 32-7/8" (835mm)

E

Corner Wall Depth

40-7/8" ( 1308mm)

F

Corner Facing Wall Width

57-13/16" (1468mm)

G

Vent Centerline Height

Rigid 29-1/4" (743mm)

Flex 26-5/8" (676mm)

H

Non-combustible facing height

13-1/4” (367mm)

I

Gas Connection Opening Height

2" (51mm)

J

Gas Connection Height

3-1/4" (83mm)

K

Gas Connection Inset

4-1/8" (105mm)

L

Gas Connection Opening Width

3-1/2" (89mm)

*

Framing depth measurement is noted with the nailing strips set as far forward on the fi rebox as possible.

The nailing strips can be adjusted back up to 1-1/2” to allow for varying thicknesses in non-combustible
material & wall fi nishes.