Hi300, Installation – Regency Hampton HI300 Medium Wood Insert User Manual
Page 16
![background image](/manuals/573806/16/background.png)
16
Hampton HI300 Wood Cast Insert
installation
918-967
05/02/11
3
HI300
Cast
adjustment
bolts
Cast
mounting
bolts
for height
adjustment.
See Step 1 to identify side casts.
See next section for recommended measurements.
If unable to align side faceplate to unit and top
faceplate further adjustments need to be made,
complete one
side at a time. Loosen all bolts on brackets (6 per side). Loosen
top and bottom bolts (Shown below).
Adjust left or right side cast plates to allow further adjustment on
faceplate. Once aligned, hold side surround in place and tighten
all bolts. If side cast height needs adjusting, loosen 2 bolts holding
cast bracket and adjust up or down.
Rear View of Unit
RECOMMENDED MEASUREMENTS
FOR SETTING SIDE CASTS
SIDE CAST ADJUSTMENTS
Stop! Read Carefully.
Enamel & Cast components are very fragile.
Use extreme care when handling.
Right Side
Cast
Left Side
Cast
1/4" (approx.) between both
sides of door and cast.
Ashlip
1/8" - 1/4" (approx.) for both sides,
between ashlip and bottom of side cast.
4-1/2" - 4-3/4" boths sides rear inside edge to fi rebox.
Important: Verify gap between cast and door did not
change when rear adjustments have been made.
Carefully open door slowly, to ensure that the door does
not rub against cast sides.
*
These are just recommended measurements.