maintenance

SECONDARY AIR TUBE REMOVAL /

INSTALLATION

DOOR CATCH ADJUSTMENT

1. Allow the stove to burn out and cool down, until cool to touch.

2. Open stove door to access secondary air tube.

3. Grasp secondary air tube fi rmly with vise grips, using a hammer tap vise

grips from right to left until air tube is released from grip. Remove.

Secondary Air

Tube

The door catch may require adjustment as the door gasket compresses after
a few fi res. The door catch compression may require adjustment to renew
seal. Removal of the spacer washer, shown in the diagram below, will allow the
catch to be moved closer to the door frame, causing a tighter seal. Remove
and replace the nuts, washer and spacer as shown

Spacer washers

3. To reinstall or replace, fi rst slide left side of tube into hole on left side air

channel. Align tab on right side air channel with notch on right hand end of
air tube. Firmly grip center of air tube with vise grips, use hammer to tap vise
grips from left to right until the tube bottoms out into the air channel on right.