Operating instructions – Regency CI2600 Large Wood Insert User Manual
Page 28
CI2600/HI400 | wood insert
28 |
operating instructions
PROVISION FOR CATALYTIC COMBUSTOR TEMPERATURE PROBE
NOTE: 1/4" drill bit required for this installation.
The CI2600/HI400 is equipped with a provision to accept a catalytic tempera-
ture monitoring device. Please follow instructions below for the installation of
the probe. Follow the user instructions of the catalytic monitoring device for
product set up and details.
1. Remove all packaging from the unit
2. Locate the precut square on the top of the unit. Lift up the metal square to
900 with a fl at head screwdriver.
3. Locate the 7/16’’ bolt below the metal. Use a 7/16’’ socket and remove the bolt.
Remove 7/16’’ bolt.
Install temperature probe
Drill hole with 1/4" drill bit
Probe
Device
4. Use a ¼’’ drill bit and drill through the hole. Make sure the drill bit size is
correct to ensure a air tight seal when the probe is installed.
5. Take your temperature probe and measure from end 3’’ and make a mark.
Insert the temperature probe to the mark.
6. Complete the installation of the CI2600/HI400. Ensure temperature probe
wire is routed behind the faceplate and to the left side of the unit. Plug the
in the monitoring device.