beautypg.com

Safety label – Regency Classic C34 Small Gas Stove User Manual

Page 6

background image

6

Regency

®

CLASSIC C34-3 Direct Vent Freestanding Gas Stove

SAFETY LABEL

This is a copy of the label that accompanies
each CLASSIC Direct Vent Freestanding Gas
Stove. We have printed a copy of the contents
here for your review. The safety label is located
on the back panel.

NOTE: Regency

®

units are constantly being

improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.

Listed:
Certified for/Certifi e pour:
Tested to:
WN# 16477

CANADA and U.S.A.

CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007

VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION

é

P
L

12" WC (2.98 kpa)
11" WC (2.73 kpa)
2.9" WC (0.72 kpa)
#52

(1.61mm)

16000 BTUH (4.69 kw/h)
32000 BTUH (9.38 kw/h)
0-4500 ft/pi (0-1372m)

PROPANE GAS STOVE:

Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude

Model C34-LP3

L

APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit

minimum selon

D bit

maximum selon

l'altitude

Calorifique
Calorifique

Modéle C34-LP3

й

й

й

й

й
й

Model/Modele:

C34-LP3

P
L

5"

WC (1.25kpa)

3.8" WC (0.94kpa)
1.1" WC (0.27kpa)
#36

(2.71mm)

16000 BTUH (4.69 kw/h)
32000 BTUH (9.38 kw/h)
0-4500 ft/pi (0-1372m)

NATURAL GAS STOVE:

Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude

Model C34-NG3

L

APPAREIL FONCTIONNANT AU

NATURAL

CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit

minimum selon

D bit Calorifique maximum selon
l'altitude

Calorifique

GAZ

Modéle C34-NG3

й

й

й

й

й
й

Model/Modele:

C34-NG3

DOOR SEAL:

Please check that the door is properly sealed.

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

297

DUPLICATE SERIAL NO.

FPI Fireplace Products International Ltd.

Delta, BC, Canada

Made in Canada/

Fabrique au Canada

Minimum Clearances to Combustibles /

Degagement Minimum

De Materiaux Combustibles

A 10"/250mm
B 6"/150mm
E 1.5"/38mm

Minimum ceiling height from

top of unit:36"/914mm

Minimum plafond hauteur en

haut de l'appareil: 36"/914mm

Minimum clearance to vent 1.25“/32mm

Serial No./ No de serie

918-490a

Back wall

Side

wall

E

Back wall

Side

wall

Side

wall

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation
Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1
en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured
Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations
Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.

For use with glass doors certified with the appliance only

This vented gas fireplace heater is not for use with air filters.

Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U.
seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec
d'autres gaz sauf si une trousse de conversion certifiée est fournie.

Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil

297

Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.

NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.

FOYER AU GAZ À ÉVACUATION -

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.