Regency

®

CLASSIC C34-3 Direct Vent Freestanding Gas Stove

19

INSTALLATION

Horizontal Venting with Two (2) 90

o

Elbows

Option V

H + H1

A)

4' Min. 6' Max.

B)

5' Min. 7' Max.

C)

6' Min. 8' Max.

Vertical Venting with Two (2) 90

o

Elbows

Option V

H

V + V1

A)

1' Min. 4' Max. 2' Min.

B)

2' Min. 5' Max. 3' Min.

C)

3' Min. 6' Max. 4' Min.

D)

4' Min. 7' Max. 5' Min.

E)

5' Min. 8' Max. 6' Min.

With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

With these options, maximum total
pipe length is 30 feet with minimum
of 6 feet total vertical and maximum
8 feet total horizontal.
Please note minimum 1 foot be-
tween 90

o

elbows is required.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

Vent restrictor position C (fully
open), refer to "Vent Restrictor
Position" section.

Vent restrictor position C (fully open), refer to "Vent Restrictor
Position" section

Lengths do not include elbow
indicated.