Component description – Summit TDC111V Service Manual User Manual
Page 9

Component description
Components and measurement values
The specified resistance values apply at room temperature (about 20°C/68°F). Values within
±10% are considered normal.
Article no.
Component
Measurement value
Comment
80 839 15
Motor 50 Hz,
220/240 V
Winding resistance:
cable colour red-white 26.5
Ω
cable colour red-blue 53.5
Ω
cable colour white-blue
27.0 Ω
Current: 0.7 A; 140 W;
2850 rpm
80 839 16
Motor 60 Hz,
220/240 V
Winding resistance:
cable colour red-white 26.5
Ω
cable colour red-blue 53.5
Ω
cable colour white-blue
27.0 Ω
Current: 0.7 A; 140 W;
3300 rpm
The motor is a 2-pin motor and is
directly connected to the fan for
internal air and the gearing for driving
the cylinder. On condenser dryers, the
motor also drives the fan for external air.
80 903 13
Capacitor
8 μF
50 Hz
80 903 14
Capacitor
6 μF
60 Hz
80 902 70
Capacitor heat pump
17 μF
50 Hz
80 902 71
Capacitor heat pump
60 Hz
80 821 28
Condensate pump
50 Hz
80 846 48
Condensate pump
60 Hz
80 762 02
EMC-filter with inductor
The filter eliminates interference to and
from the machine.
80 833 44
Thermistor
4.8 kΩ (at 25°C)
The thermistor controls temperature
regulation. If the thermistor is short-
circuited or detaches from the control
unit, the programme is stopped.
80 773 85
Thermostat 150
150°C automatic
The thermostat/overheating cut-out
stops the programme if the temperature
becomes too high.
80 792 00
Thermostat 135
135°C automatic
80 902 24
Thermostat 110
110°C automatic
80 761 04
Door switch
The front door triggers a door switch
which stops the programme when the
door is open. If the door has been opened
and closed during the programme the
machine must be restarted using the
Start/Stop button.
80 761 03
Microswitch float
Overflow guard
If both containers in the tumble dryer
are full the programme is stopped by
a float switch installed in the lower
container. “Over flow” is indicated on
the display.
Electrical connection
Condenser 1950W/10A-
2500W/16A
Vented 1950W/10A-
3000W/16A
Heat pump 1300W/10A
Heating Water Circuit
1950W/10A
The machine is delivered as single phase
and can be switched between 10 A and 16
A. The control buttons are used to make
the switch via the software. Does not apply
to Heat Pump or Heating Water Circuit.
Service Manual TD70.C
9