Fault indicators
In the case of a fault the following fault indicators are shown on the display.
Troubleshooting
S3
J1
DISPLAY
S2
S1
Display
Cause
Action
Over flow fault, Overflow
Fault, Over flow fault,
Överfyllnad, Overløbsfejl,
Overflom, Ylitulviminen,
Trop plein, Überlauf,
Troppo pieno, Desborde,
Пeрeлив вoды, Te veel
water
The microswitch is opened when a
full condensed water tank is detected.
Detection begins 30 seconds after the
programme starts. If the microswitch is
open >30 seconds the programme cycle
is stopped.
Check whether the customer has:
• Emptied the tank and restarted the
machine.
Service action:
• Clean hoses and check voltage and
resistance of drainage pump.
• Check that the float has not got
“stuck” and check the function of the
microswitch.
The auto filter is clogged, defective or
the auto filter/sealing is improper fitted.
Check whether the customer has:
• Cleaned the auto filter and installed the
auto filter/sealing properly.
Service action:
• Replace the auto filter and/or the
sealing.
H
P
(h
ea
t p
um
p)
Defective or improper installed anti-
siphon valve.
Service action:
• Clean the hose and replace the
anti-siphon valve.
The reversing valve is clogged or
defective.
Service action:
• Clean the auto filter and replace
the anti-siphon valve.
Hoses improper installed after service.
Service action:
• Check hose installation.
Max Program Time,
Max program time ,
Maximal programtid,
Maksimal programtid,
Maks programtid, Max
ohjelma-aika, Durée maxi
prog., Tijd overschreden,
Tempo max. progr.,
Duración máx prog,
Пpeвышeниe вpeмeни,
Max. Programmzeit
The programme cycle time exceeds 200
minutes. The cycle is stopped and the
programme is reset.
High ambient temperature combined
with low heater output and low
drying temperature leads to poor
condensation formation.
Poor condensation due to blocked
external air
Check whether the customer has:
• Tried spinning at a higher
speed.
• Had the machine switched off for 30
minutes before restarting.
• Good ventilation in the room.
Service action:
• Ensure that the external air has free
passage.
Service Manual TD70.C