beautypg.com

Troubleshooting – Summit TDC111V Service Manual User Manual

Page 26

background image

Fault indicators
In the case of a fault the following fault indicators are shown on the display.

Troubleshooting

S3

J1

DISPLAY

S2

S1

Display

Cause

Action

Over flow fault, Overflow

Fault, Over flow fault,

Överfyllnad, Overløbsfejl,

Overflom, Ylitulviminen,

Trop plein, Überlauf,

Troppo pieno, Desborde,

Пeрeлив вoды, Te veel

water

The microswitch is opened when a
full condensed water tank is detected.
Detection begins 30 seconds after the
programme starts. If the microswitch is
open >30 seconds the programme cycle
is stopped.

Check whether the customer has:
• Emptied the tank and restarted the
machine.

Service action:
• Clean hoses and check voltage and
resistance of drainage pump.
• Check that the float has not got

“stuck” and check the function of the
microswitch.

The auto filter is clogged, defective or

the auto filter/sealing is improper fitted.

Check whether the customer has:

• Cleaned the auto filter and installed the

auto filter/sealing properly.

Service action:

• Replace the auto filter and/or the

sealing.

H

P

(h

ea

t p

um

p)

Defective or improper installed anti-

siphon valve.

Service action:

• Clean the hose and replace the

anti-siphon valve.

The reversing valve is clogged or

defective.

Service action:

• Clean the auto filter and replace

the anti-siphon valve.

Hoses improper installed after service.

Service action:

• Check hose installation.

Max Program Time,

Max program time ,

Maximal programtid,

Maksimal programtid,

Maks programtid, Max

ohjelma-aika, Durée maxi

prog., Tijd overschreden,

Tempo max. progr.,

Duración máx prog,

Пpeвышeниe вpeмeни,

Max. Programmzeit

The programme cycle time exceeds 200
minutes. The cycle is stopped and the
programme is reset.

High ambient temperature combined
with low heater output and low
drying temperature leads to poor
condensation formation.

Poor condensation due to blocked
external air

Check whether the customer has:
• Tried spinning at a higher
speed.
• Had the machine switched off for 30

minutes before restarting.

• Good ventilation in the room.

Service action:
• Ensure that the external air has free
passage.

Service Manual TD70.C

26