CIRCUIT DIAGRAM TD70.C HWC

80 902 89 - 00

WIRES IN SOME MACHINES

INTERNAL CONNECTION

NTC 1

F

SERVICE MENU

TURN OFF POWER (S1)

WAIT FOR AT LEAST 5 SEC

HOLD S2

TURN ON POWER (S1)

PRESS S2 5 TIMES TO ENTER SERVICE MENU

PRESS STOP (S3) TO CHANGE MENU STEP

ROTATE DIAL TO CHANGE IN STEP

PRESSING START (S2) STORES AND EXITS SERVICE MENU

EL 1950 W

T2

DB

N

L1

L3

L2

CM6

CM5

CM3

INKB

CM2

MO

T1

CM4
CM1

NTC 2

WIRES IN ALL MACHINES

CABLE POSITIONS

1: THERMISTOR

2:

COINMETER

4: MOTOR, DRAIN PUMP, FLOAT SWITCH

5: DOOR SWITCH

6: COMMUNICATIONS INTERFACE

8: POWER

9: HEATING ELEMENT

RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)

VALUES WITH +/-10% ARE REGARDED AS NORMAL

COMPONENT

F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm

NTC 1: THERMISTOR 1 4 - 6 K Ohm

NTC 2: THERMISTOR 2: 4 - 6 K Ohm

EL: HEATING ELEMENT 1950W 20.5 Ohm

MO: MOTOR

T1: THERMOSTAT

T2: THERMOSTAT,

DB: DOOR SWITCH

CI: COMMUNICATIONS INTERFACE

MV: MAGNETIC VALVE 866 Ohm

S2 S3

S1

CI

F1
F2

3 Phase

F1

F2

USER SETTINGS MENU

TURN OFF POWER (S1)

WAIT FOR AT LEAST 5 SEC

HOLD S3

TURN ON POWER (S1)

PRESS S3 5 TIMES TO ENTER MENU

2011-07-07

MV

INKB

L

N

1 Phase

MO

MO

PHASE

BLACK

CM1
CM2

BROWN

CM5

CM4

CM3

GROUND

BLUE

CM6

BLACK

BLUE

YELLOW-

GREEN

FROM CONTROL UNIT

NEUTRAL

FROM CONTROL UNIT

If coin meter is selected CM1

and CM4 needs to be closed to

start the machine

(default closed with jumper)

CONNECTOR FOR COIN METER

Relay board

Service Manual TD70.C