CIRCUIT DIAGRAM TD70.C HP

80 902 90 - 02

SERVICE MENU

TURN OFF POWER (S1)

WAIT FOR AT LEAST 5 SEC

HOLD S2

TURN ON POWER (S1)

PRESS S2 5 TIMES TO ENTER SERVICE MENU

PRESS STOP (S3) TO CHANGE MENU STEP

ROTATE DIAL TO CHANGE IN STEP

PRESSING START (S2) STORES AND EXITS SERVICE MENU

RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)

VALUES WITH +/-10% ARE REGARDED AS NORMAL

COMPONENT

F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm

NTC 1: THERMISTOR 1 4 - 6 K Ohm

NTC 2: THERMISTOR 2: 4 - 6 K Ohm

AP: DRAIN PUMP: 111 Ohm

CO: COMPRESSOR

MO: MOTOR

FB: FLOAT SWITCH

DB: DOOR SWITCH

CI: COMMUNICATIONS INTERFACE

SV: SWITCHING VALVE

FA: FAN

S2 S3

S1

USER SETTINGS MENU

TURN OFF POWER (S1)

WAIT FOR AT LEAST 5 SEC

HOLD S3

TURN ON POWER (S1)

PRESS S3 5 TIMES TO ENTER MENU