beautypg.com

Summit TDC111V Service Manual User Manual

Page 19

background image

This document must not be copied without

our written pemission, and the contents

thereof must not be imparted to a third party

nor be used for any unauthorized purpose.

Contravention will be prosecuted.

Asko Appliances AB

CIRCUIT DIAGRAM TD70.C

80 902 59 - 01

SERVICE MENU

TURN OFF POWER (S1)

WAIT FOR AT LEAST 5 SEC

HOLD S2

TURN ON POWER (S1)

PRESS S2 5 TIMES TO ENTER SERVICE MENU

PRESS STOP (S3) TO CHANGE MENU STEP

ROTATE DIAL TO CHANGE IN STEP

PRESSING START (S2) STORES AND EXITS SERVICE MENU

RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)

VALUES WITH +/-10% ARE REGARDED AS NORMAL

COMPONENT

F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm

NTC 1: THERMISTOR 1 4 - 6 K Ohm

NTC 2: THERMISTOR 2: 4 - 6 K Ohm

AP: DRAIN PUMP: 111 Ohm

EL: HEATING ELEMENT 1050W 167,6 Ohm

EL: HEATING ELEMENT 1950W 90,2 Ohm

MO: MOTOR

T1: THERMOSTAT, OVERHEATING (HEATER)

T2: THERMOSTAT, OVERHEATING (HEATER)

FB: FLOAT SWITCH

DB: DOOR SWITCH

T: TRANSFORMER

S2 S3

S1

USER SETTINGS MENU

TURN OFF POWER (S1)

WAIT FOR AT LEAST 5 SEC

HOLD S3

TURN ON POWER (S1)

PRESS S3 5 TIMES TO ENTER MENU

2012-09-10

Service Manual TD70.C

19

This manual is related to the following products: