Chapter 1 Introduction

2

• Programmable Controller (32 control setpoints, OR/AND logic,

extensive triggers, programmable thresholds and delays, relay
control, event-driven data recording). Ability to block relay outputs
with a special control algorithm.

High-Class 3-phase Power meter (true RMS, volts, amps, powers,
power factors, unbalance, neutral current)

Demand Meter (amps, volts, harmonic demands)

Precise Energy and Power Demand Meter (TOU, 16 Summary
energy and demand registers for substation energy management,
accumulation of energy pulses from external watt-meters, block
and sliding demands, up to 64 energy sources)

Harmonic Analyzer (to 63rd harmonic volts and amps, directional
power harmonics and power factor, phasors, symmetrical
components)

32 digital counters for counting pulses from external sources and
numerous internal events

16 programmable timers from 1/2 cycle to 24 hours for periodic
recording and triggering operations on a time basis

1-ms satellite-synchronized clock (IRIG-B time-code input)

SNTP Time Synchronization thru Ethernet port.

Second backup power supply unit.

Additionally, the SA300 can be equipped with a 64/128-Mbyte Expansion Memory plug-in module for long-
term waveform recording.

AC/DC Inputs

The SA300 is provided with a set of fully isolated AC/DC inputs for a connection to the AC feeders and station
battery:

Four isolated AC voltage inputs (up to 690VAC direct line-to-line input voltage)

Four standard isolated AC current inputs with an extended input range up to

×3000%

overload (10A/IEC or 20A/ANSI input currents, to 150 Amps fault currents)

Optional second set of four isolated current inputs (10A/IEC or 20A/ANSI input currents)
for precise energy metering

DC voltage input (up to 300VDC) for monitoring the station battery

Digital and Analog I/O Options

The SA300 has five I/O expansion slots for removable plug-in I/O modules:

DI - Digital inputs (16 or 32 optically isolated inputs per module, up to 3 modules per
device; options for dry contacts, and wet inputs; programmable de-bounce time from 1
ms to 1 sec; free linkage to Sequence-of-Events Recorder, Fault Recorder, control
setpoints, pulse counters and Energy/TOU subsystem)

RO - Relay outputs (8 or 16 relays per module, up to 4 modules per device; unlatched,
latched and pulse operations, failsafe operation for alarm notifications; programmable
pulse width; direct remote relay control through communications)

AI/AO - Mixed analog input/output modules (four optically isolated AI and four AO with
internal power supplies per module, up to 4 modules per device; options for 0-1mA,
±1mA, 0-20mA and 4-20mA inputs and outputs;

×200% overload current for 0-1mA and

±1mA AI/AO)

Communications Options

The SA300 has extensive communications capabilities:

Three independent universal serial communications ports (RS-232, RS-422/RS-485,
up to 115,200 bps, Modbus RTU/ASCII and DNP3.0 protocols)

Infrared port (Modbus RTU/ASCII and DNP3.0 protocols)

Embedded 56K modem for communications through public telephone lines (Modbus
RTU/ASCII and DNP3.0 protocols)

Ethernet 10Base-T port (Modbus/TCP or DNP3.0/TCP protocols, up to five non-
intrusive simultaneous connections, Telnet service port)

USB 1.1 port (Modbus RTU protocol, 12 Mbps) for fast local communications and data
retrieving