beautypg.com

Robustel R3000 Lite User Guide User Manual

Page 97

background image

Robustel GoRugged R3000 Lite User Guide


RT_UG_R3000 Lite_v.1.0.0 23.12.2013 96 / 113
Confidential

cannot set new parameters of R3000 Lite at present.
An SMS command has following structure:
Password:cmd1,a,b,c;cmd2,d,e,f;cmd3,g,h,i;...;cmdn,j,k,n
SMS command Explanation:
1. Password: SMS control password is configured at Basic‐>SMS Control‐>Password, which is an optional

parameter.
a) When there is no password, SMS command has following structure: cmd1;cmd2;cmd3;…;cmdn
b) When there is a password, SMS command has following structure: Password:cmd1;cmd2;cmd3;…;cmdn

2. cmd1, cmd2, cmd3 to Cmdn, which are command identification number 0001 – 0010.

3. a, b, c to n, which are command parameters.

4. The semicolon character (‘;’) is used to separate more than one commands packed in a single SMS.

5. E.g., 1234:0001
In this command, password is 1234, 0001 is the command to reset R3000 Lite.

Cmd

Description

Syntax

Comments

Control Commands

0001

Reset Device

cmd

if no password, please use
command "cmd", or use
command" password:
cmd"
cmd1 + cmd2:
cmd1;cmd2
* - means can be null

0002

Save Parameters

cmd

0003

Save Parameters and
Reset Device

cmd

0004

Start PPP Dialup

cmd

0005

Stop PPP

cmd

0006

Switch Sim Card

cmd

0007

Clear SIM Card's Data
Limitation

cmd,simNumber

simNumber:
1 - SIM_1
2 - SIM_2