beautypg.com

13 configuration -> usb, Configuration -> usb – Robustel R3000 Lite User Guide User Manual

Page 44

background image

Robustel GoRugged R3000 Lite User Guide


RT_UG_R3000 Lite_v.1.0.0 23.12.2013 43 / 113
Confidential

serial data can be matched to this local IP address and be transmitted or
received via VPN tunnel.
Note: when you do not enable any VPN tunnel, this item will not show up.

Local Port @ Modbus

Enter the Local port for Modbus.

0

Attached serial device
type @ Modbus

Select From “Modbus RTU slave”, “Modbus ASCⅡ slave”, “Modbus RTU
master” and “Modbus ASCⅡ master”.
Modbus RTU slave: router connects to slave device which works under
Modbus RTU protocol.
Modbus ASCⅡ slave: router connects to slave device which works under
Modbus ASCⅡprotocol.
Modbus RTU master: router connects to master device which works under
Modbus RTU protocol.
Modbus ASCⅡ master: router connects to master device which works
under Modbus ASCⅡ protocol.

Modbus
RTU slave

Modbus

Slave

@

Modbus

Add the Modbus slaves which will be polled by Modbus master (router). This
section only displayed when you select “Modbus RTU master” or “Modbus
ASCII master” in “Attached serial device type”.

Null

Slave

Address

@

Modbus Slave

This connection is usually used to connect to the Modbus slave devices
which as TCP server. Enter IP address of the TCP server.

Null

Slave Port @ Modbus
Slave

Enter the port number of TCP server.

Null

ID @ Modbus Slave

Enter the ID number of TCP server.

Null

Interval Timeout @
Transparent

Over

Rlink

Serial port will queue the data in buffer and then send it to the Cellular
WAN/Ethernet WAN when it reaches the Interval Timeout in this field.

10

Attached serial device
type @ Modbus Over
Rlink

Select From “Modbus RTU slave”, “Modbus ASCⅡ slave”.
Modbus RTU slave: router connects to slave device which works under
Modbus RTU protocol.
Modbus ASCⅡ slave: router connects to slave device which works under
Modbus ASCⅡprotocol.

Modbus
RTU slave

3.13 Configuration -> USB

This section allows users to set the USB parameters.
Note: Users can insert an USB storage device, such as U disk and hard disk, into the router’s USB interface. If there is
configuration file or firmware of R3000 Lite inside the USB storage devices, R3000 Lite will automatically update the
configuration file or firmware. We will provide another file to show how to do USB automatic update.