Syslog
Item
Description
Default
Save Position
Select the save position from “None”, “Flash” and “SD”. “None” means syslog is
only saved in RAM, and will be cleared after reboot.
NONE
Log Level
Select form “DEBUG”, “INFO”, “NOTICE”, “WARNING”, “ERR”, “CRIT”, “ALERT”
and “EMERG” which from low to high. The lower level will output more syslog in
detail.
DEBUG
Keep Days
Specify the syslog keep days for router to clear the old syslog.
14
Log to Remote System
Enable to allow router sending syslog to the remote syslog server. You need to
enter the IP and Port of the syslog server.
Disable
3.33 Configuration -> Event
This section allows users to set the Event parameters.
Event
Item
Description
Default
Enable Event
Click to enable Event feature.
This feature is used to report R3000 Lite’s main running event to SNMP-TRAP or
RobustLink. There are numbers of Event code you can select, such as
“BOOT-UP”, “3G-UP”, “3G-DOWN”, etc. For example if you click “3G-UP” and
select “RobustLink” as the server, when R3000 Lite dial up to connect to 3G
network, it will send event code “3G-UP” as well as relevant information to
Disable