Setup mode, Date – RKI Instruments SC-01 User Manual
Page 27

SC-01 Operator’s Manual
Setup Mode • 22
Setup Mode
This section describes the SC-01 in Setup Mode. In Setup Mode, you can
move through a menu of screens to do the following:
•
Set the date and time
•
Perform a fresh air adjustment (part of a calibration)
•
Perform a span adjustment (part of a calibration)
•
Update the alarm point settings
•
Update the calibration frequency
Using Setup Mode
WARNING: The SC-01 is not in operation as a gas detector while in
Setup Mode. Although it will respond to gas in parts of
AIR CAL and SPAN CAL, there are no alarm indications.
1. Take the SC-01 to a non-hazardous area and turn it off if it is on.
2. Press and hold the AIR
▼
, then press and hold the POWER button.
When you hear a beep release the buttons. After a few seconds, the
first menu item in Setup Mode displays, the DATE Screen.
3. Use the AIR
▼
button to move forward through Setup Mode and the
▲
DISP button to move back through Setup Mode.
4. When you arrive at the item you wish to enter, press and release the
POWER button to enter that item.
The Setup Mode menu items are described below in the order in which
they appear while moving forward through Setup Mode.
Setting the Date and Time
Entering the DATE menu item allows you to set the date and time.
DATE
DATE