Using function cards – function card pack, Default settings – Paxton PROXIMITY compact slimline User Manual
Page 10

Operation
10
Using function cards – Function card pack
PROXIMITY Green, Amber and Red Zone cards
These 3 cards toggle the green, amber and red access levels on and off. By default all the levels are active
(this means the LEDs on the reader are lit). This in turn allows the green, amber and red PROXIMITY user
cards access.
If the PROXIMITY Green zone card is presented to the reader, the green LED will go out and the reader will
beep twice quickly. When presented for a second time the green LED comes back on and the reader again
beeps twice quickly. This is the same for each PROXIMITY colour zone card.
If the green LED on the reader is not lit, a user with a green PROXIMITY user card is denied access (red LED
flashes). This is the same for the other coloured LEDs and corresponding PROXIMITY user cards.
PROXIMITY Remote Release card
If either the PROXIMITY Card plus PIN card or the PROXIMITY Time zone card has been used. This card
can be presented to the reader to change back the function of the blue wires in order to accept an exit button.
When the card is presented, all the LEDs go out and the reader will beep twice quickly.
PROXIMITY Card plus PIN card
After this card is presented to the reader the Time zone function and exit button will not work. This card
should be swiped where a PROXIMITY compact system is combined with a volt free output from a keypad
based system. (e.g. Switch 2) . The BLUE wires on the PROXIMITY compact system are connected to the
switched contacts on the relay (COM/NO). The lock will not open until both a PROXIMITY user card is
presented to the reader and a valid user code is typed in on the keypad and the relay contacts have closed.
When the card is presented, all the LEDs go out and the reader will beep twice quickly.
PROXIMITY Time Zone card
This card is used to enable/disable the time zone function. The PROXIMITY time zone card simply toggles
the control unit between the time zone function being enabled and disabled. By default the time zone
function is disabled. If the PROXIMITY time zone card is presented to the reader, the reader beeps twice
and all the LEDs go out and come back on. The time zone function is now enabled.
A time clock can now be programmed and coloured zones can be set up. (To enable/disable coloured zones
see Green, Amber and Red Zone cards). To disable the time zone function, just present the PROXIMITY
Time zone card to the reader.
PROXIMITY Bar All Users card
This card should be used if the majority of users on the system need to be barred. The card should be
presented to the reader once. All the LEDs will go out and come back on, and the reader will beep twice
quickly. All users will now be barred. To re-enrol users back onto the system see PROXIMITY Enrolment
card.
Relay Toggle card
This card is not used with Slimline PROXIMITY compact.
Default Settings
User cards ......................................................................................................................all cards encoded will be valid
Zone LED status....................................................................................................................all LEDs/zones will be on
Squeak setting .................................................................................................................................................... activated
Door open time ................................................................................................................................................. 7 seconds
Remote button ..................................................................................................... activates release for door open time
Time zones ............................................................................................................................................................ Inactive
Relay toggle .........................................................................................................................................................Disabled