Battery replacement

1. Remove the unit from the door by removing the 4 securing screws on the rear lock assembly.

2. Remove the top two standoff screws - Fig 1.

3. Remove the access plate to reveal the battery pack. - Fig 2.

4. Unplug the lead and replace the pack with a new Paxton battery pack. - Fig 3.

(The unit will retain its settings and should not be manually reset).

5. Refit the access plate and secure.

6. Refit the unit to the door.

Fig 1

Fig 2

Fig 3

When the battery voltage falls below 4V, the user will see a delay between the card being read and

access being granted. This delay provides a warning that the battery pack should be replaced.

The warning delay starts at 2 seconds, increasing up to 10 seconds as the battery discharges with use.

Low battery warning

Recovery from a flat battery

Should the battery pack become discharged, the latch will no longer

function. This could be in the locked or unlocked state.

Holding a PP3 9V battery up to the contacts on the bottom of the unit will

allow the circuitry to operate normally.

A valid user card can then be used to open the door to access the batteries.

+ve

-ve

With the product fixed securely to the door:

1) Hold the door unlocked by presenting the fail open release card.

2) Check that the handles are running smoothly. This is best done by depressing the handle all the

way to the bottom and then releasing it as slowly as possible. If the handle is left behind at any

point, it is likely that the product has not been installed squarely enough. Check the handle on

both sides of the door.

3) If your finger is able to leave the handle, remove the unit from the door (or slacken the four

mounting screws) and see if the problem goes away. If it does, the installation onto the door is at

fault and the drilling of the mounting holes should be checked for alignment.

4) Return the door to normal operation by presenting the fail open release card again.

This test confirms the correct and free operation of the mechanical lock and also ensures that the

electronic circuits will shut down correctly preserving battery life.

Commissioning checks

The door open time should be kept to a minimum to preserve battery life.