MTS SWIFT 50 GLP Sensor Heavy Trucks User Manual
Page 25

Specifications
SWIFT 50 GLP Sensors
Hardware Overview
25
Maximum operating temperature
Low level amplifiers
Transducer interface
70°C (158°F)
50°C (122°F)
*
Contact MTS for other rim sizes.Larger diameter rims can be used, provided that overall clearance from
brake calipers and suspension components is maintained.
† Load impedance >1 k
Ω
; 0.01 µF (maximum) load capacitance.
‡ Half axle rated capacity per SAE 267.
§ Seen on the transducer for 100,000 cycles.
# The actual calibrated range may be different based on individual customer requirements. Consult the
calibration range sheet that accompanies each transducer for the correct calibration range.
** Typical value on most steel rims. Stainless steel rims typically have slightly higher modulation, but at a
lower added weight.
†† Each SWIFT sensor is calibrated on an MTS calibration machine. MTS provides complete documentation
of calibration values for each SWIFT unit. Unique calibration values are stored electronically and
transferred to the transducer interface unit (TI box) shipped with each SWIFT 50.
SWIFT 50 GLP Transducer Performance (part 2 of 2)
Parameter
Specification