MTS SWIFT 40 Sensor User Manual
Page 27

Specifications
SWIFT 40 Sensors
Hardware Overview
27
Transducer Interface
P
ARAMETER
S
PECIFICATION
Physical
Height
Width
Depth
Weight
Rack Mounting Kit
31.75 mm (1.25 in)
431.8 mm (17 in)
215.9 mm (8.5 in.)
*
1.68 kg (3 lb 11.1 oz)
Optional
*
Add 25.4 mm (1.0 in) for ground lugs.
Environmental
Ambient temperature
Relative humidity
0° C (32° F) to 50° C (122° F)
0 to 85%, non-condensing
Power Requirements
Input voltage
Supply current
Fuse
10–17 V DC
2 A typical, 3 A maximum at 12 V DC
3 A fast-blow
Angular velocity
Encoder limit
Processing limit
Encoder resolution
2,200 rpm maximum
10,000 rpm maximum
2048 counts per revolution
(512 pulses with quadrature)
Time delay (encoder tick to main output stable)
12 µs (typical)
Transducer cable length
100 ft maximum
Shunt cable length
100 ft maximum
Analog outputs
Voltage
Capacitive load
Current
Noise at output, with typical gains
±10 V range
†
(force and moment outputs)
0–5 V sawtooth (angle output)
0.01 µF maximum
6 mA maximum
7 mVpp, DC - 500 Hz (typical)
15 mVpp, DC - 500 Hz (maximum)
† Standard from MTS. Other full scale voltages can be evaluated and may be provided at special
request.
Bandwidth (bridge input to main output)
–3 dB at 30.1 kHz (typical)
90 degree at 16.6 kHz (typical)