MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-180 User Manual
Page 73

Annually
Monthly
Weekly
Daily
Calendar Time using 8 hour
Running Time rate per day
10,000
5,000
2,000
1,500
1000
500
160
40
8
Running Time-Hours
MTS
MTS
MTS
MTS
Check HPU operating pressure
and temperature
MTS
MTS
MTS
MTS
Clean control cabinet air filter,
replace if required
MTS
MTS
MTS
MTS
Inspect heat exchanger for
leaks or “flow (when off)”
MTS
MTS
MTS
MTS
Inspect pump hoses for leaks
MTS
MTS
MTS
MTS
Lubricate-grease motor
bearings (non 505)
MTS
MTS
MTS
MTS
Verify dirty filter indicators
status
MTS
MTS
MTS
MTS
Verify HPU hydraulic fluid level
MTS
MTS
MTS
MTS
Verify warning and interlock
devices
MTS
MTS
Replace all filters
MTS
MTS
Verify operation and settings of
psi control and relief valves
MTS
Check pump/motor coupling for
wear and debris
MTS
Check pump voltage and
current
MTS
Check case drain flow
MTS
MTS
MTS
MTS
Recommend MTS Hydraulix oil
sample
MTS
MTS
Recommend replacement or
rebuild of heat exchanger
MTS
Recommend replacement of
hoses
MTS
Inspect motor
bearings
Series 505G2 SilentFlo™ Hydraulic Power Unit Product Information 73
Maintenance