beautypg.com

MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-180 User Manual

Page 57

background image

Descriptions

Control

ROD On Delay (sec) - blue-green: Indicator used as a label
for the pushbutton switch below it.

ROD On Delay (sec)

ROD On Delay numeric display - pushbutton/indicator - gray:
Used to set the delay in seconds. The flow must be at or above
the trigger level for this amount of time before the next pump
motor turns on. Push the button to display the numeric keypad.
With the keypad displayed, use the number keys to define the
desired delay then press Enter to set the value and return to
the Auto Setup screen.

Minimum time for this setting is 1 second.

ROD Off Delay (sec) - blue-green: Indicator used as a label
for the pushbutton switch below it.

ROD Off Delay (sec)

ROD Off Delay numeric display - pushbutton/indicator - gray:
Used to set the delay in seconds. The flow must be below the
trigger level for this amount of time before the next pump motor
turns off. Push the button to display numeric keypad. With the
keypad displayed, use the number keys to define the desired
delay then press Enter to set the value and return to the Auto
Setup screen.

Minimum time for this setting is 10 minuets. This is intended
to prevent constant pump motor cycling when flow demand
is fluctuating slightly above and below the trigger level.

Rated Flow per Module (units) - blue-green: Indicator used
as a label for the pushbutton switch below it.

Rated Flow per Module (units)

Rated Flow per Module numeric display - pushbutton/indicator
- gray: Used to set the full flow rating of the pump modules.
Push the button to display numeric keypad. With the keypad
displayed, use the number keys to define the full flow rating
then press Enter to set the value and return to the Auto Setup
screen.

Pushbutton/Indicator. Pushbutton used to define if a flow meter
is present or not. Pressing the button alternates between the
states.

Flow Meter Present/Flow Meter Not
Present

Series 505G2 SilentFlo™ Hydraulic Power Unit Product Information 57

Operation