beautypg.com

Secondary framing – Metal Sales Secondary Framing User Manual

Page 46

background image

PSF-46

Secondary Framing

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

a

lloWable

u

niform

l

oads

in

P

ounds

Per

l

inear

f

ooT

Load TaBLeS For STandard ZeeS

(Symmetrical Flanges Only)

3'-6" Lap

Flange

Web

Flange

Max Lap

Notes:

1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them.

2. Allowable loads have been calculated in accordance with 2001 AISI Specifications.

3. Bearing must be checked using actual bearing length and loads.

4. Wind loads can be obtained by multiplying tabulated values by 1.33.

5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally.

Span in

Feet

Section

Max Lap - 2 Spans

Z-

12" x 3"

Stress

Controlling, plf

12 Ga

14 Ga

12 Ga

14 Ga

Defl. (L/180)

Controlling, plf

20 170

410 200

520

Max Lap - 3 Spans

Stress

Controlling, plf

Defl. (L/180)

Controlling, plf

12 Ga

14 Ga

12 Ga

14 Ga

22 143

335 175

430

24 123

280 150

350

25 114

255 140

325

26 105

235 131

300

28 93

202

115

260

30 81 194 100

220