beautypg.com

Image ii – Metal Sales Image II Manual User Manual

Page 2

background image

PIM-2

IMAGE II

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

P

anel

o

verview

PANEL PROFILES

SLOPE

SUBSTRATE

COVERAGE

LENGTH

AVAILABILITY

APPLICATION

FASTENING SYSTEM

FASTENERS

MATERIALS

FINISH

The minimum recommended slope for any Image II roofing panel is 3:12.

The recommended substrate is

5

/

8

" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use

a properly aligned and uniform substructure. Please note that Image II panels are not recommended for use

over open framing.

Image II panels are available in a 12" and 16" widths with a 1" rib height.

Minimum panel length is 5'-0". Maximum recommended panel length is 30'-0". Longer panels require

additional consideration in packaging, shipping, and erection. Please consult your Metal Sales branch for rec-

ommendations (see PGI-2 and 3 for locations).

Image II panels material gauges and finishes vary. Please refer to the Image II brochure/color chart.

Applications include residential and architectural buildings ranging from new construction to retrofit. The term

retrofit as applied to construction methods is to replace or rework.

Concealed direct fastening system using Truss Head Woodscrews applied through factory punched fastening

slots/groove into wood decking. Fastener spacing is 18" on center, except where extreame wind uplift

conditions exist.

The fastener selection guide should be consulted for choosing proper fasteners for specific applications.

Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-13).

1"

16" Coverage

12" Coverage

1"

1"

With Striations

With Striations

With Minor Ribs

C

C

C

PERFORMANCE TEST

UL 2218, UL790, UL263, ASTM E-1592

Steel, minimum grade 50

*

Acrylic Coated Galvalume

®

(ACG) / ASTM A 792

Prepainted Galvanized / ASTM A 792

**

PVDF Fluorocarbon

*

Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.

**

Meets both Kynar 500 and Hylar 5000 specifications.

16" Coverage

1"

C

With Minor Ribs

12" Coverage