Clip-loc – Metal Sales Clip-Loc Installation User Manual
Page 14

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 2/03
812.246.1935 (Corporate Offi ce) • www.mtlsales.us.com
13
CLIP-LOC
Care of metal panels and flashings must be exercised throughout erection. Foot traffic can cause distortion of panel and damage to
finish. Traffic over the installed system must be kept to an absolute minimum. If continuous foot traffic is necessary for mainte-
nance over certain areas of the roof, then a permanent walkway should be installed.
If metal panels are installed over open framing, do not use the roof panel as a walking platform. The roof panels will not with-
stand the weight of a person standing at the edge of the panel. Provide walking platforms to avoid any panel damage as shown
below.
When walking on the roof panels is unavoidable, walk only in the flats of the panel. Walking on the ribs can cause damage to the
panels. If Clip-Loc is installed over open framing, step in the flat of the panel only and as close to the framing as possible.
F
OOT
T
RAFFIC
Clip-Loc Panels
Foot Traffic
Framing
OVER OPEN FRAMING
Walking Platforms