Pro-panel ii / versarib 20pp – Metal Sales Pro-Panel II Installation User Manual
Page 7

© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 5/09.
6
POST FRAME
& RESIDENTIAL
PRO-PANEL II / VERSARIB 20PP
5
/
8
"
9"
36"
Anti-Syphon Groove
1. Section properties and allowable loads are calculated per AISI 2001 including 2004 Supplement.
2. Ixx and Sxx are effective section properties for deflection and bending.
3. Allowable loads/spans are calculated considering bending, shear, combined bending and shear and deflection.
4. Allowable load/span calculations do not include consideration for web crippling, fastener / connection limitations or uplift testing.
5. Allowable loads/spans do not include a 1/3 stress increase.
PRO-PANEL II ALLOWABLE SPANS
2 Equal Spans
Inward Load (psf)
Outward Load (psf)
Ga. Width Ksi
20
30
40
50
60
70
20
30
40
50
60
70
29
36
80
3'-11"
3'-2"
2'-9"
2'-5"
2'-3"
2'-0"
3'-11"
3'-2"
2'-9"
2'-5"
2'-3"
2'-1"
26
36
80
4'-5"
3'-7"
3'-1"
2'-9"
2'-6"
2'-4"
4'-6"
3'-9"
3'-3"
2'-10"
2'-7"
2'-5"
PRO-PANEL II ALLOWABLE UNIFORM LIVE LOADS (psf)
3 or More Equal
Spans
Inward Load Span
Outward Load Span
Ga. Width Ksi
1.5'
2'
2.5'
3'
3.5'
4'
1.5'
2'
2.5'
3'
3.5'
4'
29
36
80
156
90
58
41
27
18
157
90
59
41
27
18
26
36
80
199
115
75
52
35
23
210
122
79
55
35
23
PRO-PANEL II ALLOWABLE SPANS
3 or More Equal
Spans
Inward Load (psf)
Outward Load (psf)
Ga. Width Ksi
20
30
40
50
60
70
20
30
40
50
60
70
29
36
80
3'-10"
3'-4"
3'-0"
2'-8"
2'-5"
2'-2"
3'-10"
3'-4"
3'-0"
2'-8"
2'-5"
2'-3"
26
36
80
4'-2"
3'-8"
3'-4"
3'-0"
2'-9"
2'-6"
4'-2"
3'-8"
3'-4"
3'-1"
2'-10"
2'-7"
C
PRO-PANEL II ALLOWABLE UNIFORM LIVE LOADS (psf)
2 Equal Spans
Inward Load Span
Outward Load Span
Ga. Width Ksi
1.5'
2'
2.5'
3'
3.5'
4'
1.5'
2'
2.5'
3'
3.5'
4'
29
36
80
135
78
50
35
26
20
136
78
50
35
26
20
26
36
80
173
99
64
45
33
25
182
105
68
47
35
27