4 menu bar, Menu bar, User interface – Lenze 931W User Manual
Page 16
User interface
Introduction
Menu bar
4
16
HB 13.0001-EN 3.0
4.1.4
Menu bar
Сдмсс гЙем Д~к
Menu bar
Description
Configuration
The set configuration of the drive unit can be loaded or saved on a hard
disk, floppy disk, or on other storage devices connected to the PC, by means
of the commands described in the following.
z
Load
– This command enables an upload of a drive configuration that is
already stored. This configuration is only displayed and is not loaded
in the drive if the user program is in offline mode (see ”Setup” menu).
Otherwise, loading a drive configuration is only possible from level 3
(see access authorisation), as otherwise users with a lower access
authorisation could ”overwrite” all motor settings.
– If ”Load” is selected in the service level, the following
warning appears: ”Service parameters are overwritten”
Remedy: Switch-over to the operating mode ”Online level 4”.
Continue loading? If the user continues loading in spite of this
warning, all service parameters are overwritten, also those for the
resolver.
– In this case the drive might have to be dismounted and the resolver
might have to be readjusted in the loadfree state, as the resolver
adjustment has to be carried out individually for each motor and
cannot be adopted even for a motor of the same type. If the resolver
offset is set incorrectly, the motor cannot operate.
z
Save
– ”Save” stores the current settings under the destination and name
that has already been defined. If they have not yet been defined, an
automatic switch-over to ”Save as...” is effected, so that the user can
specify the memory location and name.
z
Save as
– This command saves the drive configuration in accordance with the
specification of the name and destination to be selected by the user.
z
Autosave
– This function is only provided in offline mode. If ”Autosave” is
selected, all changes are accepted and saved in the RAM memory of
the programming unit. However, this function does not replace the
”Save configuration” function.
Information
Under this menu item, the version of the operating software can be
retrieved by selecting ”About”. In addition, the Lenze address is shown.
Stop
By activating this key, the travel program is stopped. If the stop key is
activated 2 times, a quick stop with a maximum braking torque is effected.
Afterwards the drive is switched to a deenergised state.
Start#x
By activating this key, the travel program is started with the travel data set
that is currently selected in the ”Travel data sets” menu. Thereby, the
number of the current travel data set is automatically placed behind the #
symbol.
Single step
Via this switch, the single step mode can be switched on, off, or to the next
step. According to whether the single step mode is activated or
deactivated, a check mark appears on the submenu items ”On” or ”Off”. By
selecting ”On” or ”Off”, the single step mode is switched on or off.
If the single step mode is active, the subsequent travel data set which is
defined in the ”Travel data sets” menu is either first started by means of a
new starting command (single step~Next) in the user program, or via the
motor input which is configured with ”Single step”.