3 appendix, 1 code table, 1 l_dfrfg – Lenze DDS Global Drive PLC Developer Studio User Manual
Page 41: Code table, L_dfrfg, Function block library lenzeelectricalshaft.lib, 3appendix

Function block library LenzeElectricalShaft.lib
Appendix
3.1.1
L_DFRFG
3−1
L
LenzeElectricalShaft.lib EN 1.2
3
Appendix
3.1
Code table
How to read the code table:
Column
Abbreviation
Meaning
Code
C0039
1
2
…
14
15
Code C0039
Subcode 1 of code C0039
Subcode 2 of code C0039
…
Subcode 14 of code C0039
Subcode 15 of code C0039
[C0156]
Parameter value of the code can only be modified when the controller is inhibited
LCD
Keypad LCD
·
DIS: ...
display only
·
all others are parameter values
Lenze
Factory setting of the code
*
The column "Important" contains further information
Choice
1 {1
%} 99 Minimum value
{smallest step/unit}
maximum value
IMPORTAN
T
−
Additional, important explanation of the code
3.1.1
L_DFRFG
FB description:
(
Code
LCD
Possible settings
IMPORTANT
Lenze
Choice
C0750 WVpDenom
16
1 V
p
= 1
2 V
p
= 1/2
4 V
p
= 1/4
8 V
p
= 1/8
16 V
p
= 1/16
32 V
p
= 1/32
64 V
p
= 1/64
128 V
p
= 1/128
256 V
p
= 1/256
512 V
p
= 1/512
1024 V
p
= 1/1024
2048 V
p
= 1/2048
4096 V
p
= 1/4096
8192 V
p
= 1/8192
16384
V
p
= 1/16384
Denominator for gain of L_DFRFG1
C0751 dwTir
1.000
0.000 {0.001
sec}
999.900 Acceleration time T
ir
of L_DFRFG1
C0752 nMaxSpeed
3000
1 {1
rpm}
16000 Maximum catch−up speed of L_DFRFG1
C0753 dwTifForQSP
0.000
0.000 {0.001
sec}
999.900 Deceleration time T
if
for QSP od L_DFRFG1
C0754 dwThresholdFollowingError
2
. 10
9
10 {1
inc}
2000000000 Contouring error of L_DFRFG1
·
1 turn = 65535 inc
C0755 wSynWindow
100
0 {1
inc}
65535 Synchronization window of L_DFRFG1
C0756 dnOffset
0
−1000000000 {1
inc}
1000000000 Offset of L_DFRFG1
·
1 turn = 65535 inc
C0757 byFunction
0
0
no TP start
1
with TP start
C0766 bySpeedDirection
1
1
cw / ccw
2 cw
3 ccw
Rot. direction selection L_DFRFG1
Rotation CW/CCW