Function block library lenzeelectricalshaft.lib, 1 profile generator – Lenze DDS Global Drive PLC Developer Studio User Manual
Page 28

Function block library LenzeElectricalShaft.lib
Special functions
2.1.4
Homing function (L_REF)
2−18
L
LenzeElectricalShaft.lib EN 1.2
Parameter codes of the instances
VariableName
L_REF1
SettingRange
Lenze
byHomingMode
C0932
0, 1, 8, 9, 20, 21
0
dnRefOffset
C0934
−2140000000 ... 2140000000 inc
0
dnHomingSpeed
C0935
0 ... 16000 rpm
100
wTiTimeHoming
C0936
0.01 ... 650.00 s
1.00
Note!
Use the FB L_REF only in tasks with an interval time in the range from 1 ... 10msec!
Range of functions
·
Profile generator
·
Homing modes
·
Control via input signals
·
Output of status signals
·
Store the present output value after power interruption
·
Connection of the function block
2.1.4.1
Profile generator
The homing speed profile can be adapted to the application.
dwHomingSpeed
bMark_b
t
v
dnRefOffset
Abb. 2−11
Homing speed profile
wTiTimeHoming
Zero pulse
Home position
Variable
Meaning
Note
dnRefOffset
Homing point offset = number of increments after the
zero pulse
The reference is: 65536 inc = 1 revolution.
An input of up to 2140000000 incr. is possible
dnHomingSpeed
Maximum traversing speed
Entry in [rpm]. (286331153
º 16000 rpm)
wTiTimeHoming
Ramp−up/down time
linear ramp (100
º 1 s)