beautypg.com

Addressing – Lenze EMF2133IB User Manual

Page 61

background image

Commissioning

Addressing

5

EDKMF2133 DE/EN/FR 6.1

61

l

H2 Adressierung−SetSlaveAdress

Addressing

Every device connected to the bus must get an unambiguous address.

)

Note!

ƒ

If S1 − S7 = OFF, the configurations set under code C0009 will become active
when the device is switched on.

ƒ

If S1 ... S7 = ON, the configurations of all switch positions will become active
when the device is switched on.

The Lenze setting for the switches (S1 − S8) is OFF.

Switch off the voltage supply of the communication module and switch it on
again to activate the changed settings.

Valid address range: 3

… 126

(Lenze setting: 126, if C0009 = 1)

The address can be set arbitrarily
ƒ using the front switch (

^ 62)

ƒ the keypad or PC (

^ 63) or

ƒ through the master (class 2) (

^ 63)