Troubleshooting and fault elimination 9 – Lenze MDxMA-MHxMA-MFxMA-MDERA-MHERA Three-phase AC motors User Manual
Page 58

Troubleshooting and fault elimination
l
58
BA 33.0005−EN 2.0
Remedy
Cause
Fault
Incorrect direction of
rotation of the motor,
correct display on the
controller
Motor cable polarity is reversed
Check and correct polarity
Encoder cable polarity is reversed
Motor rotates normally
but does not generates the
expected torque
Motor cable interchanged cyclically
Connect the phases at the motor cable connection correctly
Motor rotates in one
direction at maximum
speed in an uncontrolled
manner
Motor cable interchanged cyclically
Check motor connection and, if necessary, correct it
Polarity of encoder cable reversed
Check encoder connection and, if necessary, correct it
Motor rotates slowly in
one direction and cannot
be influenced by the drive
controller
Polarity of motor cable and encoder
cable reversed
Check the polarity and correct it
Unsteady running
Shielding of motor cable or resolve
cable inadequate
Check shielding and earth connection
Gain of the drive controller too high
Adapt gain of the controller (see operating instructions for
drive controller)
Vibrations
Insufficiently balancing of coupling
elements or machine
Rebalance
Inadequate alignment of drive train
Realign machine, if necessary, check foundation
Loose fixing screws
Check screwed connections and tighten them if necessary
Running noises
Foreign particles inside the motor
Repair by manufacturer if necessary
Bearing damage
Surface
temperature > 140°C
Overload of the drive
l
Check overload and reduce through longer acceleration
times, if necessary
l
Check winding temperature
Heat dissipation impeded by dirt
deposits
Clean surface and cooling ribs of the drives