Mechanical installation

Preparation

5

l

26

BA 33.0005−EN 2.0

Screw−in depths − B14 flange

(

Stop!

Observe maximally permissible screw−on depth for B14 flange!

S

C

Motor type / motor size

Flange size [mm]

c max. [mm]

s

MDERA

LL056 V1

FT65

11

M5

MDERA

LL063 V1

FT75

14

M5

MDERA

LL071 V1

FT85

14

M6

MDERA

LL080 V1

FT100

16

M6

MDERA

LL090 V1

FT115

14

M8

MDERA

LL100 V1

FT130

19

M8

MDERA

LL112 V1

FT130

21

M8

MDERA

LL132 V1

FT165

22

M10

M

LLMALN063

FT75

10

M5

M

LLMALN071

FT85

10

M6

M

LLMALN080

FT100

12

M6

M

LLMALN080

FT130

16

M8

M

LLMALN090

FT115

14

M8

M

LLMALN090

FT130

16

M8

M

LLMALN100

FT130

14

M8

M

LLMALN112

FT130

16

M8

MHERA

LL080L

FT100

15

M6

MHERA

LL090L

FT115

16

M8

MHERA

LL100L

FT130

18

M8

MHERA

LL112L

FT130

19

M8

MHERA

LL132L

FT165

23

M10

5.2

Preparation

Remove the corrosion protection from the shaft ends and flanges. If necessary, remove dirt
using standard cleaning solvents.

(

Stop!

Bearings or seals must not come into contact with the solvent − material
damages.

After a long storage period (> 1 year) you have to check whether moisture has entered
the motor. For this purpose, measure the insulation resistance (measuring voltage
500 V

DC

). In case of values

£1kWper volt of rated voltage, dry the winding.