Page 26: Stop
Mechanical installation
Preparation
l
26
BA 33.0005−EN 2.0
Screw−in depths − B14 flange
(
Stop!
Observe maximally permissible screw−on depth for B14 flange!
S
C
Motor type / motor size
Flange size [mm]
c max. [mm]
s
MDERA
LL056 V1
FT65
11
M5
MDERA
LL063 V1
FT75
14
M5
MDERA
LL071 V1
FT85
14
M6
MDERA
LL080 V1
FT100
16
M6
MDERA
LL090 V1
FT115
14
M8
MDERA
LL100 V1
FT130
19
M8
MDERA
LL112 V1
FT130
21
M8
MDERA
LL132 V1
FT165
22
M10
M
LLMALN063
FT75
10
M5
M
LLMALN071
FT85
10
M6
M
LLMALN080
FT100
12
M6
M
LLMALN080
FT130
16
M8
M
LLMALN090
FT115
14
M8
M
LLMALN090
FT130
16
M8
M
LLMALN100
FT130
14
M8
M
LLMALN112
FT130
16
M8
MHERA
LL080L
FT100
15
M6
MHERA
LL090L
FT115
16
M8
MHERA
LL100L
FT130
18
M8
MHERA
LL112L
FT130
19
M8
MHERA
LL132L
FT165
23
M10
5.2
Preparation
Remove the corrosion protection from the shaft ends and flanges. If necessary, remove dirt
using standard cleaning solvents.
(
Stop!
Bearings or seals must not come into contact with the solvent − material
damages.
After a long storage period (> 1 year) you have to check whether moisture has entered
the motor. For this purpose, measure the insulation resistance (measuring voltage
500 V
DC
). In case of values
£1kWper volt of rated voltage, dry the winding.