6 Technical data (extract from data sheet)
Input for DC voltage, DC current
Transducer short circuit/break
Basic range
Accuracy
a
a
The linearization accuracy refers to the maximum measuring range. The linearization accuracy is reduced
with short spans.
Input resistance
-12 to +112 mV
-10 to +210 mV
-1.5 to +11.5 V
-0.12 to +1.12 V
-1.2 to +1.2 V
-11.2 to +11.2 V
±100
V
±240
V
±6 mV
±1 mV
±2 mV
±12 mV
R
E
1 M
R
E
470 k
R
E
470 k
R
E
470 k
R
E
470 k
R
E
470 k
Shortest span
5mV
Range start/end
freely programmable within the limits in 0.01 mV steps
-1.3 to +22 mA
-22 to +22 mA
±20
A
±44
A
burden voltage
3 V
burden voltage
3 V
Shortest span
0.5mA
Range start/end
freely programmable within the limits in 0.01 mA steps
Overrange/underrange
according to NAMUR NE 43
Sampling cycle
Channel 1 to 18: 125 ms in total
Input filter
2nd order digital filter; filter constant adjustable from 0 to 10.0 sec
Electrical isolation
see “Electrical data” on page 37 and
“Overview of the electrical isolation” on page 20
Resolution
>14 bit
Short-circuit
a
a
Programmable reaction of device, e.g. triggering alarm
Break
a
Thermocouple
not detected
detected
RTD temperature probe
detected
detected
Resistance transmitter
not detected
detected
Potentiometer
not detected
detected
Voltage
±210 mV
not detected
detected
Voltage > ±210 mV
not detected
not detected
Current
not detected