DIGI-44B Installation Guide

Installation Instructions

Shelf Mounting Instructions

The DIGI-44B comes with pre-installed feet and can be shelf mounted directly out of the box.

Rack Mounting Instructions

The DIGI-44B requires one rack unit (1 RU) of space. At least 2 inches of free air space is required on both

sides of the DIGI-44B for proper side ventilation. Avoid mounting the DIGI-44B near a power amplifier or

any other source of significant heat. It is recommended that you leave an empty rack space above and

below the DIGI-44B for additional cooling.

Remove the feet from the bottom of the chassis by unscrewing the 4 Phillips head screws inside of the

feet. Set feet aside. Attach the rack ears using the 6 Phillips head screws provided. Mount the DIGI-44B

in the desired location within the rack enclosure.

UTP Output Wiring

A compatible HDBaseT receiver is required to extend the

output signals over Twisted Pair cabling. To connect the

DIGI-44B to a compatible receiver, a Cat 6 or greater cable

with a TIA-568B crimp termination on the RJ45 connector

must be used. The Cat 6 cable must not exceed 40 meters

for 3D content. The Cat 6 cable must not exceed 70 meters

for 2D content.

IR Port Wiring

To use the IR extension capabilities of the DIGI-44B, the DIGIB-EYE (wideband IR receiver) and DIGIB-EMT

(wideband IR emitter) will need to be connected to the appropriate IR ports. DIGIB-EYE’s should be

connected to the IR RECEIVER ports and DIGIB-EMT’s should be connected to the IR EMITTER ports. After

connecting the DIGIB-EMT to the IR output, mount the IR emitter to the appropriate source gear.

*Note: Third party IR components such as connecting blocks or base stations are not compatible with the