beautypg.com

INFICON PCG55x ATM to Medium Vacuum Gauge User Manual

Page 14

background image

14

tina56e1-d (2014-01)

DeviceNet interface

Specification, data format,
communication protocol


→  [7]

Interface, physical

CAN bus

Data rate (adjustable via
switch)

125 kBaud
250 kBaud
500 kBaud (default)

(125 kBaud,
250 kBaud, 500 kBaud
programmable via
DeviceNet,

→  [4])

Node address (MAC ID)
(Adjustable via

,
, switches)

0 … 63dec (63dec default)

(0 … 63 programmable
via DeviceNet,

→  [4])

DeviceNet connector

Micro-Style, 5-pin, male

Cable

shielded, special DeviceNet
cable, 5 conductors
→  33, →  [8]

Cable length, system wiring

according to DeviceNet
specifications,

→  [7], [8]

For further information on the DeviceNet interface

→  [4]

EtherCAT interface

Specification, data format,
communication protocol


→  [11], [12]

Data rate

100 Mbps

Note address

explicit device identification

EtherCAT connector

2×RJ45, 8-pin, socket
input and output

Cable 8-pin,

shielded,

Ethernet

Patch Cable or Crossover
Cable (CAT5e quality or
higher)

Cable length

≤100 m

For further information on the EtherCAT interface

→  [6]