2 identity object, 3 s-device supervisor object – INFICON BPG402-SD ATM to Ultra-High Vacuum Gauge (DeviceNet) User Manual
Page 9

tira46e1 (2004-11) BPG402-SDv1.cp
9
Class Code 01
h
= 01
d
This object provides identification of and general information about the device.
Attribute ID
Access Rule
Name
DeviceNet
Data Type
Description of Attribute
Semantics of Values
1
Get
Revision
UINT
Revision of this object.
Note: All class definitions are
required to include this class
attribute.
The current value assigned to this
attribute is one (01). If updates that
require an increase in this value are
made, then the value of this attribute
increases by one.
2
Get
Max Instance
UINT
Maximum instance number of
an object currently created in
this class level of the device.
The largest Instance number of a
created object at this class hierarchy
level.
Attribute ID
Access Rule
NV/
V
Name
DeviceNet Data Type
Description of Attribute
1
Get
NV
Vendor ID
UINT 79 02
Manufacturer identification
Value: 633 (INFICON)
2
Get
NV
Device Type
UINT
1C
h
= Vacuum pressure gauge
3
Get
NV
Product Code
UINT
12
4
Get
NV
Revision
STRUCT
5
Get
NV
Status
WORD
6
Get
NV
Serial Number
UDINT
7
Get
NV
Product Name
SHORT STRING
BPG402-SD
Service Code
Name
Description
5 (05
h
)
Reset
0 = last installation,
1 = default installation
14 (0E
h
)
Get_Attribute_Single
Class Code 30
h
= 48
d
Attribute ID
Access
Rule
Name
DeviceNet
Data Type
Description of Attribute
Semantics of Values
1
Get
Revision
UINT
Revision of this object
The current value assigned to this at-
tribute is one (01). If updates that require
an increase in this value are made, then
the value of this attribute increases by
one.
2
Get
Max
Instance
UINT
Maximum instance number of an
object currently created in this
class level of the device.
The largest Instance number of a cre-
ated object at this class hierarchy level.
2.2 Identity Object
2.2.1 Class Attributes
2.2.2 Instance Attributes
Services
2.3 S-Device Supervisor
Object
2.3.1 Class Attributes