6 binary i/o connector – INFICON CI-100 Crucible Indexer User Manual
Page 21

2 - 5
IP
N 07
4-
54
4-
P1
B
CI-100 Crucible Indexer Operating Manual
6
Move the Pocket/Jog switch to Pocket. Press CW/CCW to move to the next
pocket.
NOTE: The indexer should stop at a position that is nearly correct. If not, check
the rear panel dip switches carefully.
7
If the pocket is not at the desired home position for that pocket, move the
Pocket/Jog switch to Jog. Push CW/CCW to jog to home for that pocket.
8
Press and hold the Calibrate switch until the displays stop blinking (about three
seconds).
9
Repeat steps 6 through 8 until all pockets are calibrated.
NOTE: When calibrating a continuous (i.e., banana) pocket, calibrate the start
position using next pocket number, then the end position as the next
pocket number. For example, on a two pocket plus one banana indexer,
Pocket 3 is the banana sweep start position, Pocket 4 is the end position.
2.6 Binary I/O Connector
The binary I/O connector controls pocket selection using a single input per pocket.
The pinout and functions match those of the Telemark 376/379 indexers.
NOTE: Select Switch #5 must be off (down) to use this connector.
Table 2-1 Binary I/O Connector
Pin
Signal
1
Ground
2
Output: Interlock Contact A
3
Output: Interlock Contact B
4
Input: Pocket 1 Select
5
Output: Pocket 1 Ready
6
Input: Pocket 2 Select
7
Output: Pocket 2 Ready
8
Input: Pocket 3 Select
9
Output: Pocket 3 Ready
10
Input: Pocket 4 Select
11
Output: Pocket 4 Ready
12
Input: Pocket 5 Select
13
Output: Pocket 5 Ready
14
Input: Pocket 6 Select
15
Output: Pocket 6 Ready
16
Ground