Important, 2mounting the control step 1, Step 2 – Hydrolevel 3100 User Manual
Page 2: Step 3, Remote mounting
2
MOUNTING THE CONTROL
STEP 1
Two mounting positions are available on the
back of the control (Fig. 1). Select which of the two positions
(2 knockouts) is best for the location of the control. Remove
the knockout.
STEP 2
Place control on the well. While holding box
against well nut, tighten well clamp screw. (Fig. 2)
BACK OF HYDROSTAT BOX
FIG. 1
FIG. 3
FIG. 2
NOTE: In the case of space restrictions, the HydroStat con-
trol may be mounted in a horizontal orientation without any
loss of function. Hydrolevel recommends vertical mounting,
when possible, for proper orientation of LED display.
STEP 3
Insert sensor ALL THE WAY into well through
the knockout (A or B) you have chosen. (Fig. 3)
IMPORTANT
Make sure that the immersion well or Electro-Well™ is installed on the boiler manufacturerʼs
designated temperature limit control tapping. Note: If installing an Electro-Well, pipe sealing compound should be
used. Teflon tape is not recommended.
REMOTE MOUNTING
The following kits are available separately for mounting
the HydroStat control box in a remote location. Each kit
includes mounting hardware and a remote sensor.
Part No.
Description
48-101
Wall/Jacket Mounting Kit with 2' sensor cord
48-102
Wall/Jacket Mounting Kit with 4' sensor cord
48-103
Wall/Jacket Mounting Kit with 10' sensor cord
48-104
Wall/Jacket Mounting Kit with 20' sensor cord
48-121
Pipe Mounting Kit with 4' sensor cord