HDA 5500 for HLB 1000 and CS 1000

- 12 -

Menu point

Setting

Setting range

Default setting

When CS 1000 is selected

Important:
The default settings of the upper and lower limits of channels 1 to 4 (LO.1 to LO.4 and Hi.1
to HI.4) correspond to the values for operating the HLB 1000 on the HDA 5500.

When operating the CS1000 on the HDA5500 please note that: The default setting ranges
pre-set in the CS 1000 for the analogue signal output forms HDA.ISO, HDA.SAE or
HDA.NAS must be changed as follows.

HDA.ISO signal:

LO.1 to

LO.4 =

0.0

Hi.1 to

HI.4 =

24.4


HDA.SAE or HDA.NAS signal:

LO.1 to

LO.4 =

0.0

Hi.1 to

HI.4 =

14.0

Allocation of switching output 1 (S.S.1)

Switching output 1 allocated to the signal

From

channel

1

Switching output 1 allocated to the signal

From

channel

2

Switching output 1 allocated to the signal

From

channel

3

Switching output 1 allocated to the signal

From

channel

4

Channel 1
Channel 2
Channel 3
Channel 4

Channel 1

Switching mode switching output 1 (S.M.1)

Switching output 1 set to switch point and

hysteresis mode

Switching output

1

set to switching window mode

SP
Win


SP

Switching direction switching output 1 (S.d.1)

Relay activated

Relay deactivated

on
oFF


on

Switch on delay switching output 1 (T.on1)

Time, in seconds, which must elapse once the particular switch
point has been reached or exceeded in order for a switching
function to occur.


0..99.99 s


0

Switch off delay switching output 1 (T.oF1)

Time, in seconds, which must elapse once the value has fallen
below the particular switch-back point in order for a switching
function to occur.

0..99.99 s


0